ALTAIR® 2X Gas Detector

 All ALTAIR 2X Gas Detectors

  • Incorporate proven XCell® sensor technology
  • Enhance worker safety, compliance and traceability
  • Minimize cost of ownership
  • Demonstrate rugged durability
 
Product Options
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S  -
    • Features the first stand-alone bump test, which eliminates the need for bottled gas!
    • Bump test anytime, anywhere
    • Based on proven science and patented sensor capabilities
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S
  • ALTAIR 2X Gas Detectors: CO, CO-HC (High Concentration), CO-H2 (Hydrogen Resistant), H2S-LC, SO2, NO2, NH3 and Cl2
  • ALTAIR 2XT Two-Tox Gas Detector: CO/H2S, CO-H2/H2S, CO/H2S-LC, CO/NO2 and SO2/H2S-LC

Low cost of ownership

  • Fastest sensor response times, lowest calibration gas flow rate on the market
  • > 4-year expected sensor life
  • 3-year warranty on instrument & most sensors (2 years on Cl2, NH3)
  • Stand-alone bump tests reduce maintenance, increase productivity (ALTAIR 2XP only)
  • 1 device can monitor 2 gases (ALTAIR 2XT only)

Increased safety awareness & real-time compliance

  • Stand-alone bump test anytime, anywhere without specific calibration gas (ALTAIR 2XP only)
  • Bump pass: green LED flash every 15s, large on-screen checkmark
  • Bump fail or expiration: red LED flash every 15s, no checkmark
  • End-of-sensor-life warning and alarm

Full-time traceability

  • Records 75 alarm events
  • 150+ hours of periodic data (ALTAIR 2X and 2XP)
  • 100+ hours of periodic data (ALTAIR 2XT)
  • Compatible with MSA GALAXY® GX2 Automated Test System and MSA Link Pro software

Rugged durability

  • Tough over-molded rubber armor
  • Survives multiple 25-ft drops onto concrete
  • Agency-certified dust- and water-tight IP67 construction
  • Intrinsically-safe design

 

Related Resources


Markets: Contractor, Fire Service, Industrial, Oil & Gas, Utilities
Applications: Confined Space, Toxic Detection

  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S
  • ALTAIR 2X Gas Detectors: CO, H2S-LC and SO2
  • ALTAIR 2XT Two-Tox Gas Detector: CO/H2S and SO2/H2S-LC
  • Available in charcoal gray and glow-in-the-dark housing.
  • Contact MSA for alternate or custom setpoints.

Bid Specification: ALTAIR 2X Gas Detectors

Standard
10153984

ALTAIR® 2XP, H2S-PULSE (10, 15), Charcoal

10153985

ALTAIR® 2XT, SO2/H2S-LC (SO2: 2, 5; H2S: 10, 15), Charcoal

10153986

ALTAIR® 2X, CO (25, 100), Charcoal

10154040

ALTAIR® 2XT, CO/H2S (CO:25, 100; H2S: 10, 15), Charcoal

10154073

ALTAIR® 2XT, CO/NO2 (CO: 25, 100; NO2: 2.5, 5), Charcoal

10154074

ALTAIR® 2X, CO-H2 (25, 100), Charcoal

10154075

ALTAIR® 2X, CO-HC (25, 100), Charcoal

10154076

ALTAIR® 2X, H2S-LC (5, 10), Charcoal

10154077

ALTAIR® 2X, SO2 (2, 5), Charcoal

10154078

ALTAIR® 2X, NO2 (2.5, 5), Charcoal

10154079

ALTAIR® 2X, NH3 (25, 50), Charcoal

10154080

ALTAIR® 2X, CI2 (0.5, 1), Charcoal

10154181

ALTAIR® 2XT, CO/H2S (CO:25, 100; H2S: 10, 15), Glow-In-The-Dark

10154184

ALTAIR® 2XT, CO/NO2 (CO: 25, 100; NO2: 2.5, 5), Glow-In-The-Dark

10154185

ALTAIR® 2X, CO (25, 100), Glow-In-The-Dark

10154186

ALTAIR® 2X, CO-H2 (25, 100), Glow-In-The-Dark

10154187

ALTAIR® 2X, CO-HC (25, 100), Glow-In-The-Dark

10154188

ALTAIR® 2XP, H2S-PULSE (10, 15), Glow-In-The-Dark

10154189

ALTAIR® 2X, H2S-LC (5, 10), Glow-In-The-Dark

10154190

ALTAIR® 2XT, SO2/H2S-LC (SO2: 2, 5; H2S: 10, 15), Glow-In-The-Dark

10154191

ALTAIR® 2X, SO2 (2, 5), Glow-In-The-Dark

10154192

ALTAIR® 2X, NO2 (2.5, 5), Glow-In-The-Dark

  • USA/Canada
    • cCSAus Class I Div 1 Groups A, B, C, D
    • Class II Div 1 Groups E, F, G Class III
    • Tamb = -40C to +60C T4
    • USA: UL 913 7th Edition
    • Canada: CSA 22.2 No. 157
  • ATEX: FTZU II 2G Ex ia IIC T4 Gb -40C to +60C
  • IEC/Australia/New Zealand: FTZU Ex ia IIC T4 Gb   -40C to +60C